Field Mount

Field-mount temperature transmitters are designed with a dual compartment housing that keeps moisture, humidity, or other contaminants from getting into the transmitter’s electronics.

YTA710 Temperature Transmitter

The YTA610 is Yokogawa’s essential class temperature transmitter. The dual-compartment structure allows a single or dual input with basic diagnostics on local parameter setting functions.

The YTA610 provides high accuracy, stability, and reliability. The housing structure adopts reliable dual-compartment structure. The sensor input can be choice of single or dual inputs. This input can accept the RTD, thermocouple, ohm, or DC millivolt. It converts the sensor input to a 4 to 20 mA DC analog signal or Fieldbus digital signal. HART 7 Protocol or FOUNDATION™ Fieldbus ITK 6 version are available. The dual input can accept two sensors calculation of the differential or average value and the sensor backup function. Sensor backup functions for automatically switches-over from the primary to the backup upon sensor failure.
By adoption of local parameter switch on the Indicator, it becomes easy to do the on-site setting work.
 
YTA610 features include:

  • Dual-compartment field-mount housing
  • Choice of HART 7, or FOUNDATION™ Fieldbus ITK 6 Protocol
  • Local Parameter Setting function (Indicator model)
  • Basic diagnosis

YTA710 Temperature Transmitter

The YTA710 is Yokogawa’s ultimate class temperature transmitter. The dual-compartment structure allows a single or dual input with advanced diagnostics on local parameter setting functions.

The YTA710 provides high accuracy, stability, and reliability. The housing structure adopts reliable dual-compartment structure. The sensor input can be choice of single or dual inputs. This input can accept the RTD, thermocouple, ohm, or DC millivolt. It converts the sensor input to a 4 to 20mA DC analog signal or Fieldbus digital signal. HART 7 Protocol, BRAIN Protocol or FOUNDATION™ Fieldbus ITK 6 version are available. The dual input can accept two sensors calculation of the differential or average value and the sensor backup function. Sensor backup functions for automatically switches-over from the primary to the backup upon sensor failure.
By adoption of local parameter switch on the Indicator, it becomes easy to do the on-site setting work.

YTA710 features include:

Dual-compartment field-mount housing
Choice of HART 7, BRAIN Protocol or FOUNDATION™ Fieldbus ITK 6 Protocol
Local Parameter Setting function (Indicator model)
Advanced diagnosis

Related items